Smoke Machine

The Eurosmoke 3000 is a professional fog machine, the most powerful in its range. Ideal for events requiring dense, even coverage. With 3070 W of power, it offers adjustable output and a range of up to 16 metres. Its accessible heating element makes it easy to maintain, and its control via DMX512 or Wireless DMX (optional) ensures maximum flexibility. Compliant with European certifications, it meets all the requirements of professionals.

ARTICLE N° 99894
The Eurosmoke 3000 is the most powerful fog machine in its range, designed to meet the needs of professional environments requiring extensive coverage and reliable performance. With an exceptional power output of 3070 W, it produces dense, homogenous smoke projected up to 16 metres away. Its capabilities make it an essential tool for venues such as theatres, outdoor concerts, immersive 4Dx cinemas and fire safety training applications.

One of the highlights of the Eurosmoke 3000 is its fully accessible heating element, designed to simplify cleaning, maintenance and component replacement. This feature not only ensures long-lasting performance, but also reduces operational downtime.

Equipped with a 5-litre tank, the Eurosmoke 3000 offers extended autonomy for events requiring continuous production. Its flow rate can be precisely adjusted from 1% to 100%, enabling it to be perfectly adapted to the specific conditions of each installation. The machine also benefits from an optimised heat-up time, for rapid availability and increased efficiency.

The Eurosmoke 3000 offers several control modes for versatile management. The LCD screen combined with a navigation wheel enables intuitive configuration in manual mode. It also features DMX512 compatibility via 5-pin XLR connectors, ensuring easy integration into complex technical installations. For added flexibility, the machine supports wireless control via Wireless DMX and optional remote controls, offering simplified remote management. A built-in timer completes its functionality, enabling automatic and continuous smoke projection cycles.

Complying with all current European certifications and anticipating future standards, the Eurosmoke 3000 offers a high level of safety and performance. These certifications attest to its compliance with the strictest quality standards.

With its sturdy chassis and versatile installation options, on the ground or suspended via lyre and truss hooks, the Eurosmoke 3000 combines power, durability and adaptability. Its advanced design and features make it a high-performance technical solution for large-scale events.
Continuous flow
 Yes
DMX chain
 Yes
Power
 3000
Type of liquid
 Water base
Screen
 Yes
Weight
 15 kg
DMX control
 Wired
  • Eurosmoke 3000 fog machine
  • Power connector type: PowerCon True1
  • Power: 3070 W
  • Warm-up time: Approx. 8 minutes
  • Projection distance: 15 to 16 metres
  • Flow control: Adjustable from 1% to 100% in 1% increments
  • Positioning: Horizontal and vertical (360°)
  • Fluid consumption:
  • Maximum flow (100%): > 250 ml/min
  • Continuous flow (30%): > 50 ml/min
  • Reservoir capacity: 5 L
  • Protection rating (IP): IP20
  • Temperature protection :
  • Heating element: Bimetallic thermostat with opening
  • Pump: Thermal fuse
  • Temperature control system: Thermocouple / Microprocessor
  • Control panel: LCD screen with navigation wheel
  • Connection interface: 5-pin XLR input and output
  • Control modes: Manual, Remote control (wired or wireless), DMX512, Timer
  • Optional accessories: Wired remote control, Wifi DMX, Wireless DMX
  • Fuse: 16 A resettable fuse
  • Voltage: 230 V, 50 Hz
  • Operating temperatures: +5°C to +45°C
  • Dimensions :
  • Length: 568.5 mm
  • Width: 289 mm
  • Height : 251 mm (406 mm with tank)
  • Weight: 16 kg (empty)
  • Certifications:
  • The Eurosmoke 3000 machine complies with all current and future European standards, guaranteeing safe and reliable use in all professional environments.
  • European directives :
  • Directive 2006/42/EC (Machinery)
  • Directive 2014/30/EC (Electromagnetic Compatibility)
  • Directive 2011/65/EC (RoHS)
  • Directive 2014/35/EU (Low Voltage)
  • Harmonised standards applied :
  • EN 60335-1:2012 and subsequent amendments (A11:2014, A13:2017, A1:2019, A14:2019, A2:2019, A15:2021)
  • EN 55014-1 and EN 55014-2 (CISPR 14-1/2)
  • EN 61000-3-2 and EN 61000-3-3
  • EN IEC 61000-4 series (4-2 to 4-11)
  • ETSI EN 301 489-1 and EN 301 489-3
  • The components and protection systems have been validated in accordance with the following standards:
  • IEC 60695-2-2 : Needle burner test
  • IEC 60695-2-11 : Glow wire resistance test (550°C to 850°C)
  • IEC 60691 : Thermal protection
  • IEC 61058-1 : Switch test
  • IEC 60068-2-78 : Resistance to humidity
  • IEC 60664-1 : Overvoltage test
  • IEC 60730-2-8 : Testing of thermostats
  • IEC 60068-2-75 : Mechanical resistance
Applicable European Directives :
Machinery Directive 2006/42/EC
Low Voltage Directive 2006/95/EC and 2014/35/EU (Harmonisation of legislation)
RoHS Directive 2011/65/EC

Safety Standards :
EN 60335-1:2012 + Amendments A11:2014, A13:2017, A1:2019, A14:2019, A2:2019, A15:2021
Household and similar electrical appliances - Safety
IEC 60695-2-2 : Needle burner test
IEC 60384-14 : Capacitor overload test
IEC 61058-1 : Testing of switches (cycle life and deformation at high temperature)
IEC 60664-3 : Testing of coatings on printed circuit boards
IEC 60068-2-78 : Moisture resistance test to ensure correct operation after transport
IEC 60695-10-2 : Test of resistance to high temperatures (125°C) of plastics and polymers
IEC 60695-2-11 : Glow-wire heat and fire test (550°C, 750°C, 850°C)
IEC 60664-1 : Overvoltage test
IEC 60730-1 & 2-8 : Testing of capillary thermostats as safety components
IEC 62477-1 : Tests on voltage transformer and converter circuits
IEC 60068-2-75 : Mechanical resistance with spring hammer (0,5J)
EMC standards (Electromagnetic Compatibility) :
EN 55014-1:2021 (CISPR 14-1) : Requirements for electromagnetic emissions
EN 55014-2:2021 (CISPR 14-2): Requirements for electromagnetic immunity
ETSI EN 301 489-1 V2.2.3: EMC compatibility for radio equipment and services
Standards for Harmonics and Voltage Fluctuations :
EN 61000-3-2 (2019 + A1/2021) : Limitation of harmonic current emissions (≤16 A per phase)
EN 61000-3-3 (2013 + A1/2019 + A2/2021) : Limitation of voltage variations and fluctuations
Electromagnetic immunity standards :
EN 61000-4-2 (2009) (IEC 61000-4-2 Ed2 2008) : Electrostatic discharge immunity tests
EN 61000-4-3 (2006 + A1/2008 + A2/2010) (IEC 61000-4-3 2006 + A1/2007 + A2/2010) : Immunity to electromagnetic fields
EN 61000-4-4 (2012) (IEC 61000-4-4 2012) : Immunity to fast electrical transients
EN 61000-4-5 (2014 + A1/2017) (IEC 61000-4-5 2014 + A1/2017) : Immunity to shock waves
EN 61000-4-6 (2014) (IEC 61000-4-6 2013) : Immunity to conducted disturbances induced by radio fields
EN 61000-4-11 (2020) (EN IEC 61000-4-11 2020) : Immunity to voltage dips, short interruptions and variations.